ROLL LOAD CELL
Features: Load cell for straight supports. Insensitive to stresses in 2 axes excluding the measurement one. Protection against overloads.
Applications: measure of tension tapes, tessil, paper, rubber, nylon, metallic laminated, flexographic printing presses etc.
Click to enlarge image
Material | Steel |
Nominal load | 2500, 5000, 10000, 20000, 30000 N |
Limit load | 200 % F.S. |
Breaking load | 500 % F.S. |
Nominal load deflection | 0,10 mm |
Supply voltage | Maximum 18 V dc |
Sensitivity | 1 mV/V |
Output tollerance | 0,1 % F.S. |
Zero tollerance | 1 % F.S. |
Linearity | 0,1 % F.S. |
Hysteresis | 0,03 % F.S. |
Reapeatability | 0,1 % F.S. |
Input resistance | 350-360 ohm |
Output resistance | 350-353 ohm |
Insulation resistance | >= 2000 Mohm |
Creep (30 Minutes) | 0,03 % F.S. |
Thermal compensation | -10 / +40°C (14 / +104°F) |
Operating temperature | -20 / +70°C (-4 / +158°F) |
Temperature deviation zero | 0,003 % F.S. / °C |
Temperature deviation full scale | 0,002 % F.S. / °C |
Protection class | IP 54 |
Connection | Panel connector CR2R-07APNS |
Standard cable length | Loose female connector CR2P-07ASNS-10, connection cable 6 x 0,35 (length to be defined) |
Type | CONNECTOR MIL 4P IT3106A-14S |
Length | 5 - 10 m (body lead cell not connected shield) |
Pin A | - IN |
Pin B | - OUT |
Pin C | + OUT |
Pin D | + IN |
Optional | CONNECTOR 4P 4-20 mA S154 |
Length | 5 - 10 m (body lead cell not connected shield) |
Pin A | 4 mA |
Pin C | 20 mA |
General precautions to be followed in the installation and assembly of load cells: